EM60-changes
This commit is contained in:
@@ -380,3 +380,64 @@ script#tool-view-template(type="text/x-template")
|
||||
|
|
||||
| and spindle type. The VFD must be rebooted after changing
|
||||
| the above settings.
|
||||
|
||||
|
||||
.notes(v-if="tool_type.startsWith('EM60')")
|
||||
h2 Notes
|
||||
p Set the following using the VFD's front panel.
|
||||
table.modbus-regs.fixed-regs
|
||||
tr
|
||||
th Address
|
||||
th Value
|
||||
th Meaning
|
||||
th Description
|
||||
tr
|
||||
td.reg-addr P0.0.03
|
||||
td.reg-value 2
|
||||
td Modbus
|
||||
td Control mode
|
||||
tr
|
||||
td.reg-addr P0.0.04
|
||||
td.reg-value 9
|
||||
td Modbus
|
||||
td Frequency source A
|
||||
tr
|
||||
td.reg-addr P0.1.00
|
||||
td.reg-value 0
|
||||
td Source A
|
||||
td Frequency source
|
||||
tr
|
||||
td.reg-addr P4.1.00
|
||||
td.reg-value 3
|
||||
td 9600 BAUD
|
||||
td Must match #[tt baud] above
|
||||
tr
|
||||
td.reg-addr P4.1.01
|
||||
td.reg-value 0
|
||||
td 8N2
|
||||
td Data format
|
||||
tr
|
||||
td.reg-addr P4.1.02
|
||||
td.reg-value 1
|
||||
td Bus id
|
||||
td Must match #[tt bus-id] above
|
||||
tr
|
||||
td.reg-addr P4.1.03
|
||||
td.reg-value 2
|
||||
td No delay
|
||||
td Communications response delay
|
||||
tr
|
||||
td.reg-addr P4.1.04
|
||||
td.reg-value 0
|
||||
td No timeout
|
||||
td Communications timeout
|
||||
tr
|
||||
td.reg-addr P4.1.05
|
||||
td.reg-value 1
|
||||
td RTU
|
||||
td Modbus format
|
||||
p
|
||||
| Other settings according to the
|
||||
|
|
||||
a(href="https://buildbotics.com/upload/vfd/em60.pdf",
|
||||
target="_blank") EM60 VFD manual
|
||||
Reference in New Issue
Block a user