| and spindle type. The VFD must be rebooted after changing
| the above settings.
.notes(v-if="tool_type.startsWith('EM60')")
h2 Notes
p Set the following using the VFD's front panel.
table.modbus-regs.fixed-regs
tr
th Address
th Value
th Meaning
th Description
tr
td.reg-addr P0.0.03
td.reg-value 2
td Modbus
td Control mode
tr
td.reg-addr P0.0.04
td.reg-value 9
td Modbus
td Frequency source A
tr
td.reg-addr P0.1.00
td.reg-value 0
td Source A
td Frequency source
tr
td.reg-addr P4.1.00
td.reg-value 3
td 9600 BAUD
td Must match #[tt baud] above
tr
td.reg-addr P4.1.01
td.reg-value 0
td 8N2
td Data format
tr
td.reg-addr P4.1.02
td.reg-value 1
td Bus id
td Must match #[tt bus-id] above
tr
td.reg-addr P4.1.03
td.reg-value 2
td No delay
td Communications response delay
tr
td.reg-addr P4.1.04
td.reg-value 0
td No timeout
td Communications timeout
tr
td.reg-addr P4.1.05
td.reg-value 1
td RTU
td Modbus format
p
| Other settings according to the
|
a(href="https://buildbotics.com/upload/vfd/em60.pdf",
target="_blank") EM60 VFD manual