script#tool-view-template(type="text/x-template") #tool h1 Tool Configuration .pure-form.pure-form-aligned fieldset .pure-control-group label(for="tool-type") tool-type select(v-model="config.tool['selected-tool']", name="tool-type", @change="change_selected_tool") option(v-for="tool in toolList", :value="tool.id", :disabled="tool.disabled", :class="{ 'heading-option': tool.disabled }") {{tool.name}} templated-input(v-for="templ in template.tool", :name="$key", v-if="show_tool_settings($key)" :model.sync="config.tool[$key]", :template="templ") label.extra(slot="extra", v-if="$key == 'tool-enable-mode' || $key == 'tool-direction-mode'") | Pin {{templ.pin}} io-indicator(:name="$key", :state="state") fieldset(v-if="is_pwm_spindle") h2 PWM Spindle templated-input(v-for="templ in template['pwm-spindle']", :name="$key", :model.sync="config['pwm-spindle'][$key]", :template="templ") fieldset(v-if="is_modbus") h2 Modbus Configuration templated-input(v-for="templ in template['modbus-spindle']", :name="$key", :model.sync="config['modbus-spindle'][$key]", :template="templ", v-if="show_modbus_field($key)") h2 Modbus Status .pure-control-group(title="VFD connection status") label connection tt {{modbus_status}} .pure-control-group(title="Numerical status reported by VFD") label status tt {{state.ss || 0}} .pure-control-group(title="Speed reported by VFD") label speed tt {{state.s | fixed}} label.units RPM fieldset.modbus-program( v-if="is_modbus && tool_type != 'HUANYANG VFD' && tool_type != 'REDLINE VFD' && tool_type != 'EM60'") h2 Active Modbus Program p(v-if="$root.modified") | (Click #[tt(class="save") Save] to activate the selected | #[b tool-type].) table.modbus-regs.fixed-regs tr th Index th Command th Address th Value th Failures tr(v-for="(index, reg) in regs_tmpl.index", v-if="state[reg + 'vt']", :class="{warn: get_reg_fails(reg)}") td.reg-index {{index}} td.reg-type {{get_reg_type(reg)}} td.reg-addr {{get_reg_addr(reg)}} td.reg-value {{get_reg_value(reg)}} td.reg-fails {{get_reg_fails(reg)}} button.pure-button-secondary(@click="customize") Customize button.pure-button-secondary(@click="clear", v-if="tool_type == 'CUSTOM MODBUS VFD'") Clear button.pure-button-secondary(@click="reset_failures") Reset Failures fieldset(v-if="tool_type == 'CUSTOM MODBUS VFD'") h2 Edit Modbus Program table.modbus-regs tr th Index th Command th Address th Value tr(v-for="(index, reg) in config['modbus-spindle'].regs", is="modbus-reg", :index="index", :model.sync="reg", :template="template['modbus-spindle'].regs.template", v-if="!index || reg['reg-type'] != 'disabled' || config['modbus-spindle'].regs[index - 1]['reg-type'] != 'disabled'") .notes(v-if="tool_type == 'HUANYANG VFD'") h2 Notes p Set the following using the VFD's front panel. table.modbus-regs.fixed-regs tr th Address th Value td Meaning th Description tr td.reg-addr PD000 td.reg-value 0 td Unlock td Unlock parameters tr td.reg-addr PD001 td.reg-value 2 td RS485 td Command source tr td.reg-addr PD002 td.reg-value 2 td RS485 td Speed/frequency source tr td.reg-addr PD163 td.reg-value 1 td Modbus ID td Must match #[tt bus-id] above. tr td.reg-addr PD164 td.reg-value 1 td 9600 baud td Must match #[tt baud] above. tr td.reg-addr PD165 td.reg-value 3 td 8 bit, no parity, RTU mode td Must match #[tt parity] above. p | Other settings according to the | a(href="https://buildbotics.com/upload/vfd/Huanyang-VFD-manual.pdf", target="_blank") Huanyang VFD manual | | and spindle type. .notes(v-if="tool_type.startsWith('NOWFOREVER VFD')") h2 Notes p Set the following using the VFD's front panel. table.modbus-regs.fixed-regs tr th Address th Value th Meaning th Description tr td.reg-addr P0-000 td.reg-value 2 td Modbus communication td Command source tr td.reg-addr P0-001 td.reg-value 0 td Main frequence X td Select frequency source tr td.reg-addr P0-002 td.reg-value 6 td Modbus communication td Main frequency X tr td.reg-addr P0-055 td.reg-value 1 td Modbus ID td Must match #[tt bus-id] above tr td.reg-addr P0-056 td.reg-value 2 td 9600 baud td Must match #[tt baud] above tr td.reg-addr P0-057 td.reg-value 0 td 1 start, 8 data, no parity, 1 stop td Must match #[tt parity] above .notes(v-if="tool_type.startsWith('DELTA VFD015M21A')") h2 Notes p Set the following using the VFD's front panel. table.modbus-regs.fixed-regs tr th Address th Value th Meaning th Description tr td.reg-addr Pr.00 td.reg-value 3 td RS-485 td Source of frequency command tr td.reg-addr Pr.01 td.reg-value 3 td RS-485 with STOP td Source of operation command tr td.reg-addr Pr.88 td.reg-value 1 td Modbus ID td Must match #[tt bus-id] above tr td.reg-addr Pr.89 td.reg-value 1 td 9600 baud td Must match #[tt baud] above tr td.reg-addr Pr.92 td.reg-value 3 td 8 bit, no parity, RTU mode td Must match #[tt parity] above tr td.reg-addr Pr.157 td.reg-value 1 td Modbus mode td Communication mode p | Other settings according to the | a(href="https://buildbotics.com/upload/vfd/Delta_VFD015M21A.pdf", target="_blank") Delta VFD015M21A VFD manual | | and spindle type. .notes(v-if="tool_type.startsWith('YL600')") h2 Notes p Set the following using the VFD's front panel. table.modbus-regs.fixed-regs tr th Address th Value th Meaning th Description tr td.reg-addr P00.01 td.reg-value 3 td Modbus RS-485 td Start / stop command source tr td.reg-addr P03.00 td.reg-value 3 td 9600 baud td Must match #[tt baud] above tr td.reg-addr P03.01 td.reg-value 1 td Modbus ID td Must match #[tt bus-id] above tr td.reg-addr P03.02 td.reg-value 5 td 8 bit, no parity, 2 stop td Must match #[tt parity] above tr td.reg-addr P03.04 td.reg-value 500 td RS-485 max delay td Time in milliseconds tr td.reg-addr P07.15 td.reg-value 5 td RS-485 td Frequency source p | Other settings according to the | a(href="https://buildbotics.com/upload/vfd/YL620-A.pdf", target="_blank") YL600 VFD manual | | and spindle type. .notes(v-if="tool_type.startsWith('SUNFAR')") h2 Notes p Set the following using the VFD's front panel. table.modbus-regs.fixed-regs tr th Address th Value th Meaning th Description tr td.reg-addr F0.0 td.reg-value 2 td Serial communication td Frequency source tr td.reg-addr F0.2 td.reg-value 1002 td Serial communication td Control source tr td.reg-addr F4.0 td.reg-value 0104 td Modbus, no parity, 9600 baud td Must match #[tt parity] and #[tt baud] above tr td.reg-addr F4.1 td.reg-value 1 td Bus ID td Must match #[tt bus-id] above tr td.reg-addr F4.4 td.reg-value 3 td Seconds td Communication timeout p | Other settings according to the | a(href="https://buildbotics.com/upload/vfd/Sunfar-E300.pdf", target="_blank") Sunfar E300 VFD manual | | and spindle type. .notes(v-if="tool_type.startsWith('OMRON')") h2 Notes p Set the following using the VFD's front panel. table.modbus-regs.fixed-regs tr th Address th Value th Meaning th Description tr td.reg-addr C071 td.reg-value 5 td 9600 BAUD td Must match #[tt baud] above tr td.reg-addr C072 td.reg-value 1 td Bus ID 1 td Must match #[tt bus-id] above tr td.reg-addr C074 td.reg-value 0 td No parity td Must match #[tt parity] above tr td.reg-addr C075 td.reg-value 2 td 2 stop bits td Serial stop bits tr td.reg-addr C076 td.reg-value 4 td Deceleration stop td Communication error action tr td.reg-addr C077 td.reg-value 500 td 0.5 seconds td Communication error timeout tr td.reg-addr C078 td.reg-value 1 td 1 milisecond td Communication wait time tr td.reg-addr C096 td.reg-value 0 td Modbus-RTU td Communication mode tr td.reg-addr P200 td.reg-value 0 td Standard td Modbus mapping tr td.reg-addr P400 td.reg-value 0 td Big endian td Communication byte order p | Other settings according to the | a(href="https://buildbotics.com/upload/vfd/omron_i570_mx2.pdf", target="_blank") OMRON MX2 VFD manual | | and spindle type. The VFD must be rebooted after changing | the above settings. .notes(v-if="tool_type.startsWith('V70')") h2 Notes p Set the following using the VFD's front panel. table.modbus-regs.fixed-regs tr th Address th Value th Meaning th Description tr td.reg-addr F001 td.reg-value 2 td Communication port td Control mode tr td.reg-addr P0.0.04 td.reg-value 9 td Modbus td Frequency source A tr td.reg-addr P0.1.00 td.reg-value 0 td Source A td Frequency source tr td.reg-addr P4.1.00 td.reg-value 3 td 9600 BAUD td Must match #[tt baud] above tr td.reg-addr F002 td.reg-value 2 td Communication port td Frequency setting selection tr td.reg-addr F163 td.reg-value 1 td Slave address td Must match #[tt bus-id] above tr td.reg-addr F164 td.reg-value 1 td 9600 BAUD td Must match #[tt baud] above tr td.reg-addr F165 td.reg-value 3 td 8 data, no parity, 1 stop, RTU td Must match #[tt parity] above p | Other settings according to the | a(href="https://buildbotics.com/upload/vfd/stepperonline-v70.pdf", target="_blank") Stepper Online V70 VFD manual